loading

Professional On Oxygen And Nitrogen Gas Generation Solution.

CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 1
CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 1

CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda

CI-PC96 is a micro-oxygen analyzer, which is an intelligent analyzer based on microprocessor. The sensor used in this system is a fuel cell oxygen sensor, which can measure 0-25% oxygen concentration, but in the environment of 0-1000ppm oxygen concentration, the measurement is the best.

    oops...!

    no product data.

    Go to homepage
    1 (32)

    Product principle

    CI-PC96 is a micro-oxygen analyzer, which is an intelligent analyzer based on microprocessor. The sensor used in this system is a fuel cell oxygen sensor, which can measure 0-25% oxygen concentration, but in the environment of 0-1000ppm oxygen concentration, the measurement is the best.

    Measure range

    0-10/100/1000ppm/1 %/25 % O2

    Sensor principle

    Fuel cell type

    Accuracy

    0.01-9.99ppm O2±5% FS

    10.0-99.9ppm O2±3% FS

    100-1000ppm O2±5% FS

    Repeatability

    0.01-9.99ppm O2.5±5% FS

    10.0-99.9ppm O2±1.5% FS

    100-1000ppm O2±1% FS

    Stability

    0.01-9.99ppm O2.5±5% FS/7d

    10.0-99.9ppm O2±1.5% FS/7d

    100-1000ppm O2±1% FS/7d

    Response time

    T90<60s (25℃ )

    Switch output

    2 sets, Relay contact point capacity: 24V DC, 0.2A

    Power supply

     CL-PC96 : 85- 264VAC  50/60Hz

    CI-PC961 : 24VDC, Power consumption less than 20VA

    Communication

    RS485 (standard) / RS232 ( standard )

    Environment temperature

    0-45℃ Environment Humidity: <80% RH

    Sample gas pressure

    Atmospheric conditions±10% (Gas outlet should be atmospheric conditions)

    Analyzer size

    Cl-PC96: L*W*D = 144mm*144mm*251mm

    Cl-PC961: L*W*D = 144mm*144mm*190mm

    USER EVALUATE

    CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 3
    Industry experience
    Having been in the industry for years, we know the market situation and industry requirements more clearly than most manufacturers.
    CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 4
    Market area
    We have accumulated extensive knowledge about the quality standards as well as market needs of thesecountries.
    CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 5
    Team introduction
    That is our highly-qualified employees. We have R&D experts, designers, QC professionals, and other highly qualified employees.
    CI-PC96 Trace Oxygen Analyzer - Zhongsu Hengda 6
    Product advantages
    They outperform their competitors when it comes to durability and performance, deeply trusted by both domestic andforeign customers.

    FAQ

    The target market of our brand has been continuously developed over the years. For more information, please reach our team, we are more than happy to help.

    1
    How to get a prompt quotation?
    When you send us inquiry, please kindly tell us the below technical information.

    1) O2/N2/H2 Flow rate: ____Nm3/h

    2) O2/N2/H2 Purity: ____%

    3) O2/N2/H2 Discharge pressure: ____Bar

    4) Voltages and Frequency: _____V/PH/HZ

    5) Application or use for which industry.

    We will recommend the most suitable equipment for you according to your needs.

    2
    How long is your delivery time?
    Generally it is 10-50 working days depending on your order.
    3
    What is the terms of payment?
    T/T, L/C, etc.
    4
    What is the standard of package?
    he equipment is packed in wooden cases of export standard
    5
    Do you accept OEM business?
    Yes, we are OEM supplier.
    6
    What kind of certificate you have ?
    We have ISO9001, ISO13485,CE,SGS
    7
    Do you have similar customer cases?
    Our equipment is used in a wide range of industries and has rich customer cases.You can tell me the application industry and country of the device, and we will provide you with cases.
    8
    How to install the equipment after purchase?
    You can choose the remote video guide of the engineer or on-site installation.
    9
    What if there is a after-sales problem?
    Hengda provide guarantees for the equipment in 12 months. And out of the warranty period, we continue to provide service.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data

    The company has developed into a first-class professional supplier of air separation equipment boasting the integration of scientific research and production capacities in China. 

    CONTACT US
    Contact: Blair Sun
    Tel: +86 15850254955
    Email:Sales005@szhdjh.com.cn
    WhatsApp: +86 15850254955
    Address: 6/F, Building 8, Hengfuwei Industrial Park, No. 48 Zoumatang Road, Mudu Town, Wuzhong District, Suzhou, China
    Copyright © 2025 Suzhou Hengda Purification Equipment Co., Ltd. - www.nitrogengenerators.com.cn | Sitemap | Privacy Policy